The Rectangular Smoke Damper – Class I Leakage Rated with 3V Blades is engineered for smoke control applications requiring maximum air tightness and safety. Featuring precision-formed galvanized steel frames and 3V blades with edge seals, it ensures minimal air leakage and reliable operation under high temperature or emergency smoke conditions.

Product Features

Class I leakage performance (per AMCA 500-D or UL555S)
3V blade design for optimal air seal and strength
Galvanized or stainless steel construction
Optional electric or pneumatic actuator
Designed for horizontal or vertical installation
Factory-tested for airflow and leakage integrity

Technical Specifications

Frame MaterialGalvanized steel
Frame Material Thickness16 ga. (1.5mm)
Frame Type5 in. x 1in. (127mm x 25mm)
hat channel
Blade ActionParallel
Blade MaterialGalvanized steel
Blade Material
Thickness
16 ga. (1.5mm)
Blade Type3V
Blade OrientationHorizontal
LinkagePlated steel out of airstream, concealed in jamb
Axle Bearings316SS
Axle MaterialPlated steel
Blade SealsSilicone
Jamb SealsStainless Steel
MountingVertica/Horizontal

Space Envelopes

BromingHvac

Externally mounted actuators always require space outside of the damper sleeve. The “S” dimension illustrates the clearance required
for various available actuators.
Worst case space envelopes shown below. Exact dimensions may vary based on specifice damper configuration. Consult factory for
specific space envelope if necessary.

Contained Actuator Option

Dampers can be ordered with a “contained actuator option”. This option will result in the actuator being oriented such that it extends
no more than 11
⁄2 inches above or below the sleeve. Note that some damper configurations that are 11 inches high or less will have the
OCI mounted on the side opposite the actuator when the contained actuator option is selected.
BromingHvac

Sleeve and Sideplate Dimensions

The drawings below and corresponding table show the position of the SMD-201 damper when mounted in a factory sleeve (“A”
dimension). The standard mounting locations provide enough space for the mounting of actuators, controls and allow space for
installation of retaining angles and duct connections. The following options may affect the range of available mounting locations:
smoke detector, NEMA 7 enclosure, transitions, security bars, grille tabs.
The standard location of a damper mounted in a factory sleeve (“A” dimension) is shown below. The damper can be positioned at
other locations within a range of 6 in. (152mm) to 16 in. (406mm) for the “A” dimension.

BromingHvac
BromingHvac
BromingHvac

NOTE: Entire damper frame is not required to be installed within the wall. The damper
blades, when closed should be contained within the wall.

Transitioned Damper Dimensions

When a smoke damper is being used in conjunction with round or oval ductwork, the damper can be supplied in a factory sleeve
with round or oval transitions on both ends of the sleeve. Dampers should be ordered to the duct dimensions. Drawings below
show overall damper size.

BromingHvac

*These dimensions are furnished approximately 1/4 in. (6mm) undersize, except round and oval dimensions which are approximately 1/8 in. (3mm) undersize.
Ts = (2)(Sleeve Thickness)

Multiple Section Dampers

Dampers larger than maximum single section size are supplied as a factory assembly of two or more sections of equal size. The
following figures show maximum damper section size and assembly configurations for multi-section dampers.