Centrifugal fans / product range
Centrifugal fans draw air through an inlet and discharge it from a scroll housing. This listed range covers 857–7,939 m³/h airflow and 302–3,359 Pa pressure across several model sizes and speeds.
Compare model duty, speed, motor power and outlet arrangement with your duct system and available installation space.

Centrifugal fan overview
A centrifugal fan uses a rotating impeller inside a scroll-shaped casing. Air enters through the inlet, gains energy at the impeller and leaves through the outlet. Select a model by the airflow and pressure required at the actual operating point.

Air direction and outlet layout affect duct connections, transitions and the space needed around the fan.
Follow the air path
The supplied range lists model sizes from 2.8A to 6A, with multiple speed and duty combinations.
Compare listed models
Check the selected motor rating, supply, controls, mounting base, discharge direction and service clearance.
Review selection factorsModel data / airflow + pressure
Use these listed model points to shortlist a size and speed. Final selection depends on the system operating point and the performance curve for the exact configuration.
| Model | Speed | Airflow | Pressure | Power |
|---|---|---|---|---|
| 2.8A | 2,900 rpm | 1,330 m³/h | 970 Pa | 1.1 kW |
| 3A | 2,900 rpm | 1,715 m³/h | 1,209 Pa | 1.1 kW |
| 3A | 1,450 rpm | 857 m³/h | 302 Pa | 0.55 kW |
| 3.2A | 2,900 rpm | 1,975 m³/h | 1,270 Pa | 1.5 kW |
| 3.2A | 1,450 rpm | 991 m³/h | 320 Pa | 0.55 kW |
| 3.5A | 2,900 rpm | 2,723 m³/h | 1,640 Pa | 2.2 kW |
| 3.5A | 1,450 rpm | 1,362 m³/h | 411 Pa | 0.75 kW |
| 3.6A | 2,900 rpm | 2,930 m³/h | 1,650 Pa | 3 kW |
| 3.6A | 1,450 rpm | 1,470 m³/h | 410 Pa | 0.75 kW |
| 4A | 2,900 rpm | 4,065 m³/h | 2,150 Pa | 5.5 kW |
| 4A | 1,450 rpm | 2,032 m³/h | 537 Pa | 1.1 kW |
| 4.5A | 2,900 rpm | 5,788 m³/h | 2,721 Pa | 7.5 kW |
| 4.5A | 1,450 rpm | 2,894 m³/h | 680 Pa | 1.1 kW |
| 5A | 2,900 rpm | 7,939 m³/h | 3,359 Pa | 11 kW |
| 5A | 1,450 rpm | 3,790 m³/h | 840 Pa | 2.2 kW |
| 6A | 1,450 rpm | 6,859 m³/h | 1,209 Pa | 4 kW |
| 6A | 960 rpm | 4,541 m³/h | 530 Pa | 1.5 kW |
Airflow, pressure, speed and power are shown in the units supplied for the listed configurations. Request the current fan curve and motor details for the selected model.
How a centrifugal fan works
The casing collects air leaving the impeller and guides it toward the discharge. The outlet direction, duct transitions and system resistance all affect how the fan fits into an air-handling layout.
Provide a clear approach to the inlet and check the inlet connection against the duct or equipment layout.
Air moves outward through the impeller passages. The selected wheel, speed and motor define the available performance.
Confirm outlet direction, transition geometry and nearby clearances before fixing the fan location.
Applications
Start with required airflow and static pressure, then confirm the selected model against the air conditions, installation and operating schedule.
Use the system duty and duct layout to compare the required operating point with available fan data.
Check air volume, inlet conditions, access and the connection between the fan and the equipment enclosure.
Account for elbows, transitions, filters, grilles and dampers when estimating system resistance.
Compare the previous duty, outlet arrangement, footprint, electrical supply and service access.
Selection guide
A suitable centrifugal fan must meet the required duty and fit the project’s mechanical and electrical conditions.
| Selection factor | Project information to confirm | Fan data to review |
|---|---|---|
| Airflow | Required volume for supply, exhaust or equipment ventilation. | Airflow at the selected model’s operating pressure. |
| Static pressure | Duct length, fittings, grilles, filters, dampers and outlet arrangement. | Fan curve and pressure data for the exact size and speed. |
| Fan size and speed | Available footprint, sound constraints and operating schedule. | Model size and speed variants in the performance schedule. |
| Motor and power | Site voltage, phase, starting method and control requirements. | Motor power, nameplate data, wiring diagram and compatible controls. |
| Air conditions | Air temperature, moisture, dust or other process conditions. | Materials and limits approved for the selected model. |
| Installation | Inlet and outlet direction, supports, access and maintenance clearance. | Outline drawing, discharge orientation and installation instructions. |
Record the required volume and whether the fan supplies or exhausts air.
Include duct, fittings and terminal devices rather than selecting from free-air flow alone.
Match the duty point to its curve and verify motor, outlet, mounting and air-condition limits.
For a selection review, provide the required airflow, calculated static pressure, duct sketch, air conditions, power supply and installation clearances.
Fan type comparison
Both move air, but their airflow direction and installation geometry differ. Compare the actual duty and model data before choosing a fan type.
| Consideration | Centrifugal fan | Axial fan |
|---|---|---|
| Air direction | Air enters the impeller and leaves through an outlet in the scroll housing. | Air moves generally parallel to the fan shaft. |
| Installation layout | Plan for inlet access, casing footprint, outlet direction and duct transitions. | Plan for the fan diameter, straight-through path and mounting arrangement. |
| Selection basis | Compare airflow and pressure on the selected model curve. | Compare airflow and pressure on the selected model curve. |
| Best next step | Share the duct layout and duty point for model review. | Share the duct layout and duty point for model review. |
Installation planning
Confirm the final arrangement against the selected model drawing and site conditions before installation.

Operation + inspection
Follow the selected model’s installation and maintenance instructions. Isolate power and follow site procedures before inspection or service.
Look for obstructions or buildup at accessible duct openings, grilles and connected equipment.
Check for visible damage, loose supports or unusual vibration. Use the manufacturer’s instructions for adjustments.
Maintain clearance around the motor and have wiring or control issues checked by a qualified person.
Common questions
A centrifugal fan draws air through an inlet and moves it outward through a rotating impeller into a scroll housing, then discharges it through an outlet.
The supplied model data spans 857–7,939 m³/h airflow and 302–3,359 Pa pressure across the listed sizes and speeds.
Start with the required airflow and system static pressure. Match that duty point to the performance curve for the exact model, speed and motor configuration.
A centrifugal fan discharges air from its impeller into a scroll casing; an axial fan moves air generally along the shaft. Compare their model curves and installation geometry for the project.
Send the required airflow, static pressure, duct layout, air conditions, electrical supply, outlet direction, available space and quantity.
Confirm temperature, dust, moisture and material compatibility against the limits of the selected model before specifying it.
The supplied schedule lists speed and power but not complete voltage or control details. Confirm nameplate, wiring and control requirements for the chosen configuration.
Centrifugal fan project inquiry
Share the airflow, static pressure, air conditions, duct arrangement and electrical supply. We can compare your requirements with the listed centrifugal fan configurations.