Need Specifications or a Quote?
Share your ventilation project requirements and our engineers will reply within 12 hours with technical specs, pricing, and lead time.
Request for Quote (#2)
Factory-direct supply
OEM available
Global shipping

HVAC fans for project requirements

Find the fan that fits your system.

Compare axial, centrifugal, inline duct, mixed flow and customized fans for commercial, industrial and infrastructure ventilation.

Start with the conditions you know: airflow, static pressure, application, installation space or an existing model.

Product selection starts with project duty, fit and required documentation.
Axial fan with red impeller and steel housing
Centrifugal fan housing
Airflow + pressureStart with the operating point
Fan families · system conditions · project data
AirflowRequired volume and duty
Static pressureResistance across the system
Installation fitSpace, mounting and access
Project documentsData needed for review

Fan portfolio

Choose a fan family for the job it needs to do.

Compare the main fan types, then share your duty point and installation conditions for a project-specific review.

Centrifugal fan with red inlet cone
02 / HIGHER PRESSURE

Centrifugal fans

For duct systems and applications where pressure and controlled air movement matter.

Discuss centrifugal fans
Compact inline duct fan
03 / DUCTED INSTALLS

Inline duct fans

Compact fan options for ducted systems where diameter, space and service access shape the fit.

Discuss inline duct fans
Mixed flow fan
04 / BALANCED DUTY

Mixed flow fans

Balanced airflow and pressure for installations with demanding space constraints.

Discuss mixed flow fans
Customized smoke exhaust fan
05 / PROJECT SPECIFIC

Customized fans

Review housing, motor, material, mounting and other configuration details when a standard model does not fit the project.

Discuss a custom fan

System first

Good fan selection starts with the air path around it.

Ducts, filters, fittings, mounting and service access all affect the final operating point.

Project conditions

Share the details that change the fan choice.

Free air volume alone does not describe how a fan will perform in a finished system. Include the resistance and installation conditions you already know.

  • Airflow + pressureRequired CFM or m³/h, static pressure, and the operating point if available.
  • Application + air streamVentilation, exhaust, smoke extraction, process air, temperature or humidity conditions.
  • Fit + electrical supplyFan size, duct diameter, mounting direction, available space, voltage and frequency.
  • Quantity + documentsProject quantity, delivery location, drawing, schedule or replacement model reference.
Share project conditions
Centrifugal fan housing and air path details
Review the fan and the system togetherAir path · construction · installation

Performance at a glance

Compare reference ranges by fan family.

Use these indicative ranges to identify a starting point. Confirm the selected model against its performance curve and your system conditions.

Fan familyAirflow rangeStatic pressure rangeReview with
Axial fans382–3,827 CFM 650–6,500 m³/h0.28–1.25 in. wg 70–310 PaDuty point, size, motor, noise and mounting
Inline duct fans129–1,707 CFM 220–2,900 m³/h0.60–2.79 in. wg 150–693 PaDuct diameter, inlet configuration and voltage
Centrifugal fans504–4,671 CFM 857–7,939 m³/h1.21–13.50 in. wg 302–3,359 PaModel curve, speed, motor and system resistance
Mixed flow fansProject specificModel specificCurve, duct geometry and installation space
Customized fansProject specificProject specificDrawing or sample, duty point and materials

Ranges are indicative and model-dependent. Final performance must be confirmed from the selected model’s curve before approval.

Applications

Match the fan to the environment it serves.

Different environments bring different airflow, pressure, temperature, access and documentation needs.

Underground parking garage with ventilation ducts
01 / PARKING GARAGES

Plan daily ventilation and smoke exhaust separately.

Review system resistance, operating modes, temperature duty, controls and maintenance access.

Cleanroom ventilation ducts and air handling equipment
02 / CLEANROOMS + LABS

Maintain pressure and filtration performance.

Check room pressure relationships, filter resistance, leakage, cleanability and validation needs.

Commercial building atrium with air distribution grilles
03 / COMMERCIAL BUILDINGS

Coordinate comfort with plant room constraints.

Consider outdoor air, noise, duct connections, service access and retrofit shutdown windows.

Metro tunnel with ventilation equipment
04 / TUNNELS + INFRASTRUCTURE

Coordinate ventilation with safety systems.

Confirm emergency duty, temperature rating, redundancy, controls and required project documents.

From requirement to quotation

Move from project data to a fan review.

Send the information you already have. A drawing or replacement model can help, but you can start with the duty and application.

Start a project inquiry
  1. 01

    Share the duty

    Provide airflow, static pressure, application, quantity and delivery location where available.

  2. 02

    Review fan fit

    Compare fan family, model curve, motor, installation space and project conditions.

  3. 03

    Confirm quotation details

    Review the selected configuration, drawings, performance information and delivery requirements.

Common questions

Useful answers before you specify a fan.

Need a project-specific answer? Send the conditions you have and ask us to review them.

Ask about your project
What information should I send for a quotation?

Share airflow, static pressure, application, fan size, voltage, quantity, operating temperature and delivery location where available. A drawing or existing model reference also helps. You can start with partial information.

How do I choose between axial and centrifugal fans?

Axial fans are often considered for higher airflow with lower system resistance. Centrifugal fans are often considered when the system needs higher pressure. Confirm the operating point against the selected model’s curve and installation conditions.

Are the ranges on this page guaranteed for every model?

No. The ranges are indicative and model-dependent. Final performance should be confirmed against the selected fan’s performance curve before approval.

Can fan housing, motor or mounting be customized?

Selected projects may support changes to the housing, motor, materials, mounting and other configuration details after engineering review.

Can you provide technical drawings and fan curves?

Drawings, dimensions, performance data and installation information should be confirmed for the selected model before procurement.

Can I request a quote before all specifications are complete?

Yes. Share the project application and whatever conditions you have. The team can identify which additional details are needed for a fan review.

Have a fan requirement to review?

Share your application and the specifications you already have. We can identify the next information needed for a quotation.
Not sure which fan family fits?
Describe the air path, pressure requirement and installation space. Start with what is available.
Share Your Project Details
联系我们页面表单