Need Specifications or a Quote?
Share your ventilation project requirements and our engineers will reply within 12 hours with technical specs, pricing, and lead time.
Request for Quote (#2)
Factory-direct supply
OEM available
Global shipping

Centrifugal fans / product range

Centrifugal Fans for HVAC Systems

Centrifugal fans draw air through an inlet and discharge it from a scroll housing. This listed range covers 857–7,939 m³/h airflow and 302–3,359 Pa pressure across several model sizes and speeds.

Compare model duty, speed, motor power and outlet arrangement with your duct system and available installation space.

Industrial centrifugal fan with red inlet cone and scroll housing
857–7,939 m³/hListed airflow range
302–3,359 PaListed pressure range
960–2,900 rpmListed speed options
0.55–11 kWListed motor power range

Centrifugal fan overview

Match the fan to the system duty.

A centrifugal fan uses a rotating impeller inside a scroll-shaped casing. Air enters through the inlet, gains energy at the impeller and leaves through the outlet. Select a model by the airflow and pressure required at the actual operating point.

Centrifugal fan diagram showing the inlet, volute housing and top outlet
01 / AIR PATH

Inlet, impeller and outlet

Air direction and outlet layout affect duct connections, transitions and the space needed around the fan.

Follow the air path
Side view of a centrifugal fan showing scroll casing and outlet
02 / MODEL RANGE

Compare size and speed

The supplied range lists model sizes from 2.8A to 6A, with multiple speed and duty combinations.

Compare listed models
Centrifugal fan motor mounted beside the scroll housing on a steel base
03 / MOTOR + INSTALLATION

Confirm power and access.

Check the selected motor rating, supply, controls, mounting base, discharge direction and service clearance.

Review selection factors

Model data / airflow + pressure

Centrifugal fan performance range.

Use these listed model points to shortlist a size and speed. Final selection depends on the system operating point and the performance curve for the exact configuration.

ModelSpeedAirflowPressurePower
2.8A2,900 rpm1,330 m³/h970 Pa1.1 kW
3A2,900 rpm1,715 m³/h1,209 Pa1.1 kW
3A1,450 rpm857 m³/h302 Pa0.55 kW
3.2A2,900 rpm1,975 m³/h1,270 Pa1.5 kW
3.2A1,450 rpm991 m³/h320 Pa0.55 kW
3.5A2,900 rpm2,723 m³/h1,640 Pa2.2 kW
3.5A1,450 rpm1,362 m³/h411 Pa0.75 kW
3.6A2,900 rpm2,930 m³/h1,650 Pa3 kW
3.6A1,450 rpm1,470 m³/h410 Pa0.75 kW
4A2,900 rpm4,065 m³/h2,150 Pa5.5 kW
4A1,450 rpm2,032 m³/h537 Pa1.1 kW
4.5A2,900 rpm5,788 m³/h2,721 Pa7.5 kW
4.5A1,450 rpm2,894 m³/h680 Pa1.1 kW
5A2,900 rpm7,939 m³/h3,359 Pa11 kW
5A1,450 rpm3,790 m³/h840 Pa2.2 kW
6A1,450 rpm6,859 m³/h1,209 Pa4 kW
6A960 rpm4,541 m³/h530 Pa1.5 kW

Airflow, pressure, speed and power are shown in the units supplied for the listed configurations. Request the current fan curve and motor details for the selected model.

How a centrifugal fan works

Air turns through the impeller and scroll housing.

The casing collects air leaving the impeller and guides it toward the discharge. The outlet direction, duct transitions and system resistance all affect how the fan fits into an air-handling layout.

01 / INLET

Air enters at the fan eye

Provide a clear approach to the inlet and check the inlet connection against the duct or equipment layout.

02 / IMPELLER

The rotating wheel adds energy

Air moves outward through the impeller passages. The selected wheel, speed and motor define the available performance.

03 / DISCHARGE

The scroll casing guides the outlet flow

Confirm outlet direction, transition geometry and nearby clearances before fixing the fan location.

Applications

Where to evaluate a centrifugal fan.

Start with required airflow and static pressure, then confirm the selected model against the air conditions, installation and operating schedule.

01 / HVAC DUCT SYSTEMS

Supply and exhaust ventilation

Use the system duty and duct layout to compare the required operating point with available fan data.

02 / EQUIPMENT AIRFLOW

Ventilation around machinery

Check air volume, inlet conditions, access and the connection between the fan and the equipment enclosure.

03 / DUCTED EXHAUST

Air paths with fittings and accessories

Account for elbows, transitions, filters, grilles and dampers when estimating system resistance.

04 / FAN REPLACEMENT

Replacement in an existing installation

Compare the previous duty, outlet arrangement, footprint, electrical supply and service access.

Selection guide

Select by airflow and pressure together.

A suitable centrifugal fan must meet the required duty and fit the project’s mechanical and electrical conditions.

Selection factorProject information to confirmFan data to review
AirflowRequired volume for supply, exhaust or equipment ventilation.Airflow at the selected model’s operating pressure.
Static pressureDuct length, fittings, grilles, filters, dampers and outlet arrangement.Fan curve and pressure data for the exact size and speed.
Fan size and speedAvailable footprint, sound constraints and operating schedule.Model size and speed variants in the performance schedule.
Motor and powerSite voltage, phase, starting method and control requirements.Motor power, nameplate data, wiring diagram and compatible controls.
Air conditionsAir temperature, moisture, dust or other process conditions.Materials and limits approved for the selected model.
InstallationInlet and outlet direction, supports, access and maintenance clearance.Outline drawing, discharge orientation and installation instructions.
STEP 01 / DEFINE

Set the design airflow

Record the required volume and whether the fan supplies or exhausts air.

STEP 02 / CALCULATE

Estimate system pressure

Include duct, fittings and terminal devices rather than selecting from free-air flow alone.

STEP 03 / VERIFY

Check the exact configuration

Match the duty point to its curve and verify motor, outlet, mounting and air-condition limits.

For a selection review, provide the required airflow, calculated static pressure, duct sketch, air conditions, power supply and installation clearances.

Fan type comparison

Centrifugal or axial fan?

Both move air, but their airflow direction and installation geometry differ. Compare the actual duty and model data before choosing a fan type.

ConsiderationCentrifugal fanAxial fan
Air directionAir enters the impeller and leaves through an outlet in the scroll housing.Air moves generally parallel to the fan shaft.
Installation layoutPlan for inlet access, casing footprint, outlet direction and duct transitions.Plan for the fan diameter, straight-through path and mounting arrangement.
Selection basisCompare airflow and pressure on the selected model curve.Compare airflow and pressure on the selected model curve.
Best next stepShare the duct layout and duty point for model review.Share the duct layout and duty point for model review.

Compare axial fan configurations

Installation planning

Plan the casing, outlet and service space.

Confirm the final arrangement against the selected model drawing and site conditions before installation.

  • Inlet clearanceKeep the inlet approach clear and confirm the transition connection.
  • Outlet directionMatch the fan discharge to the duct route and available turn space.
  • Base and supportsCheck the mounting base, structural support and access for service.
  • Motor and wiringVerify nameplate power, supply, controls and electrical access.
Review a fan configuration
Centrifugal fan outlet and mounting base for installation planning

Operation + inspection

Keep the fan and air path serviceable.

Follow the selected model’s installation and maintenance instructions. Isolate power and follow site procedures before inspection or service.

01 / AIR PATH

Check inlet and outlet openings

Look for obstructions or buildup at accessible duct openings, grilles and connected equipment.

02 / FAN ASSEMBLY

Inspect the casing and supports

Check for visible damage, loose supports or unusual vibration. Use the manufacturer’s instructions for adjustments.

03 / MOTOR

Keep electrical service accessible

Maintain clearance around the motor and have wiring or control issues checked by a qualified person.

Common questions

About centrifugal fans.

What is a centrifugal fan?

A centrifugal fan draws air through an inlet and moves it outward through a rotating impeller into a scroll housing, then discharges it through an outlet.

What airflow and pressure range is listed?

The supplied model data spans 857–7,939 m³/h airflow and 302–3,359 Pa pressure across the listed sizes and speeds.

How do I choose the correct centrifugal fan size?

Start with the required airflow and system static pressure. Match that duty point to the performance curve for the exact model, speed and motor configuration.

How does a centrifugal fan differ from an axial fan?

A centrifugal fan discharges air from its impeller into a scroll casing; an axial fan moves air generally along the shaft. Compare their model curves and installation geometry for the project.

What information is needed for a fan quotation?

Send the required airflow, static pressure, duct layout, air conditions, electrical supply, outlet direction, available space and quantity.

Can a centrifugal fan handle heated or dusty air?

Confirm temperature, dust, moisture and material compatibility against the limits of the selected model before specifying it.

Are motor voltage and controls included in this model range?

The supplied schedule lists speed and power but not complete voltage or control details. Confirm nameplate, wiring and control requirements for the chosen configuration.

Centrifugal fan project inquiry

Send the duty point for model review.

Share the airflow, static pressure, air conditions, duct arrangement and electrical supply. We can compare your requirements with the listed centrifugal fan configurations.

Request a centrifugal fan quote

Related fan range

Comparing straight-through airflow?

Explore axial fans for ventilation projects